{"product_id":"ventilator-breathecir-a10004-adult-1-8-double-limb","title":"Ventilator - BreatheCir A10004 Adult 1.8 - Double Limb","description":"\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIERAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cspan data-subtree=\"aimfl\" data-processed=\"true\"\u003eThe \u003c\/span\u003eVentilator – BreatheCir A10004 Adult 1.8 (Double Limb)\u003c!--TgQPHd|||[]--\u003e is a medical-grade respiratory delivery circuit designed to transport mechanical ventilation gases safely and reliably between critical care ventilators and adult patients\u003c!--TgQPHd|||[[[null,null,null,null,null,null,null,null,null,null,null,null,[247864,null,0]]]]--\u003e. Engineered as a continuous double-limb (dual-leg) configuration, this assembly features smoothbore tubing corridors that combine structural flexibility with exceptionally low airflow resistance. Equipped with dual high-capacity inline water traps and an extra monitoring extension arm, it provides a secure, closed-loop treatment corridor that manages moisture condensation effectively while shielding delicate intensive care equipment from backpressure and fluid contamination. \u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIERAA\" data-complete=\"true\" data-processed=\"true\"\u003e\u003c\/div\u003e\n\u003cdiv data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=iSz92d_10\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAAIEhAA\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\n\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],[],null,1]]--\u003e\n\u003c\/div\u003e\n\u003cul data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFBAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFBAC\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDouble-Limb Circuit Architecture:\u003c!--TgQPHd|||[]--\u003e Configured as a full dual-leg inspiratory and expiratory loop system to support complete closed-circuit respiratory management on advanced ventilators.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e \u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFBAH\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eLow-Resistance Smoothbore Interior:\u003c!--TgQPHd|||[]--\u003e Designed with a smooth internal profile that limits gas turbulence, guarantees consistent delivery pressure, and reduces the patient's mechanical work of breathing.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e \u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFBAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDual Condensate Water Traps:\u003c!--TgQPHd|||[]--\u003e Equipped with two self-sealing inline water traps that isolate and collect moisture rain-out, drastically lowering the risk of bacterial accumulation and ventilator fluid invasion.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e \u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFBAR\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eY-Connector with Sampling Port:\u003c!--TgQPHd|||[]--\u003e Incorporates a standard distal Y-piece outfitted with an integrated monitoring cap, enabling convenient connection for capnography (EtCO₂) sampling and gas detection.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e \u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFBAW\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003eTransparent Anti-Kinking Tubing:\u003c!--TgQPHd|||[]--\u003e Fabricated from soft, resilient, and highly transparent medical polymers that actively resist pinching or kinking while allowing unobstructed visual tracking of circuit conditions.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=iSz92d_2h\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAAIGRAA\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\n\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],[],null,1]]--\u003e\n\u003c\/div\u003e\n\u003cul data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAC\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eProduct Name \u0026amp; Model:\u003c!--TgQPHd|||[]--\u003e Ventilator – BreatheCir A10004 – Adult 1.8.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAD\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePrimary Circuit Length:\u003c!--TgQPHd|||[]--\u003e 1.8 meters (approximately 6 feet).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAE\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSupplemental Link Assembly:\u003c!--TgQPHd|||[]--\u003e Includes an additional 0.4-meter smoothbore limb segment.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAF\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMoisture Management:\u003c!--TgQPHd|||[]--\u003e 2 x integrated adult-sized mechanical water traps.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAG\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMaterial Matrix:\u003c!--TgQPHd|||[]--\u003e High-clarity, non-toxic, latex-free, and flexible medical-grade polymers.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAH\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eConnection Interface:\u003c!--TgQPHd|||[]--\u003e Standard international tapered couplings compliant with ISO structural specifications.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSterility \u0026amp; Hygiene Profile:\u003c!--TgQPHd|||[]--\u003e Supplied clean, individually sealed, and rated for single-patient disposable use only (do not autoclave).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIGhAJ\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePrimary Clinical Settings:\u003c!--TgQPHd|||[]--\u003e Intensive Care Units (ICU), Critical Care Transport, Operating Theatres, and Post-Anesthesia Recovery Bays.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SA Healthcare (Pty) Ltd","offers":[{"title":"Default Title","offer_id":53083444183320,"sku":"VEN-BCA10004A","price":282.66,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1910\/0399\/files\/Screenshot_2026-10-29_132648-removebg-preview.png?v=1793273329","url":"https:\/\/shop.vertice.co.za\/products\/ventilator-breathecir-a10004-adult-1-8-double-limb","provider":"Vertice Healthcare (Pty) Ltd ","version":"1.0","type":"link"}