{"product_id":"resuscitator-t-piece-infant-neo-i","title":"Resuscitator ( T-Piece) Infant NEO-I","description":"\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIDRAA\" data-complete=\"true\" data-processed=\"true\"\u003eThe \u003cspan class=\"rQesXe MPyX\"\u003eNEO-I\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e is a premium, manually operated pneumatic infant resuscitator designed to deliver safe, precise, and controlled airway management for newborns and infants weighing under 10 kg. Fully compliant with the latest guidelines from \u003cspan class=\"rQesXe MPyX\"\u003eILCOR, AAP (NRP), and the AHA\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e, the NEO-I is strongly recommended for the resuscitation of premature infants. By delivering operator-independent, consistent pressures, it helps successfully establish Functional Residual Capacity (FRC) while dramatically reducing clinical fatigue compared to traditional manual bag-mask squeezing.\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIDRAA\" data-complete=\"true\" data-processed=\"true\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003cstrong\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=HpYogc_12\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIExAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIExAC\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eGuidelines-Compliant Design:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e Engineered to align with strict global neonatal resuscitation protocols (AAP\/NRP, ILCOR, and AHA), providing a safer and more reliable alternative to self-inflating manual resuscitation bags.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIExAD\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eControlled PIP \u0026amp; Consistent PEEP:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e Delivers highly accurate and controllable Peak Inspiratory Pressure (PIP) along with reliable Positive End-Expiratory Pressure (PEEP). This helps improve lung volume, protect fragile lung tissue from barotrauma, and keep the alveoli open.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIExAE\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003e100% Pneumatic Operation:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e Purely gas-driven and requiring \u003cspan class=\"rQesXe MPyX\"\u003eno electrical power supply\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e, making it exceptionally reliable and continuously operational during critical power failures or emergency mobile patient transfers.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIExAF\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eIntegrated Precision Manometer:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e Features an easy-to-read, fast-acting mechanical airway pressure gauge measuring from \u003cspan class=\"rQesXe MPyX\"\u003e-10 to 80 cmH₂O (mbar)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e to enable non-stop visual tracking of delivery pressures.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIExAG\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eAdjustable Fail-Safe Pressure Relief (Pmax):\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e Outfitted with a dedicated safety override dial to control the maximum pressure limit, ensuring pressures never accidentally exceed safe clinical thresholds (factory pre-set to a default of 40 cmH₂O).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIExAH\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eErgonomic \u0026amp; Portable Layout:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e Built as a lightweight, compact system with a built-in top handle. It mounts seamlessly onto neonatal carts, walls, incubators, or radiant warmers across labor wards, NICUs, and transport teams.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=HpYogc_30\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAC\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eTarget Patient Type:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e Neonates and infants weighing up to 10 kg (ideal for premature infants)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAD\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eGas Flow Input Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e 5 L\/min to 15 L\/min\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAE\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eOxygen Concentration Control:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e 21% to 100% (dependent on your external gas supply or blender source)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAF\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eManometer Gauge Scale:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e -10 to 80 cmH₂O (mbar)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAG\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003eMax Pressure (Pmax) Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e 4 to 60 cmH₂O\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAH\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003ePIP Performance Parameters (By Flow Rate):\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAI\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAJ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e@ 5 L\/min: 1 – 55 cmH₂O\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAK\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e@ 8 L\/min: 2 – 57 cmH₂O\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAL\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e@ 10 L\/min: 3 – 58 cmH₂O\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e@ 15 L\/min: 5 – 60 cmH₂O\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAN\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003ePEEP Performance Parameters (By Flow Rate):\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAO\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAP\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e@ 5 L\/min: 0 – 8 cmH₂O\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e@ 8 L\/min: 1 – 17 cmH₂O\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAR\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e@ 10 L\/min: 1.5 – 23 cmH₂O\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIFRAS\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e@ 15 L\/min: 3 – 26 cmH₂O\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SA Healthcare (Pty) Ltd","offers":[{"title":"Default Title","offer_id":53059805774104,"sku":"RESINFNEOI","price":22818.85,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1910\/0399\/files\/download.webp?v=1793094165","url":"https:\/\/shop.vertice.co.za\/products\/resuscitator-t-piece-infant-neo-i","provider":"Vertice Healthcare (Pty) Ltd ","version":"1.0","type":"link"}