{"product_id":"aed-intelligent-public-access-defibrillator","title":"AED - CUSP1 - with Disposable Battery","description":"\u003cp\u003eThe i-PAD CU-SP1 is an automated external defibrillator (also known as an AED or PAD). The i-PAD CUSP1 is designed for minimally trained individuals. It provides simple and direct voice prompts and instructions for straightforward rescue operation. It is lightweight and battery powered for maximum portability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e• Easy and Simple Operation\u003cbr\u003e• Efficient and effective e-cube Biphasic technology (BTE type)\u003cbr\u003e• Lightweight and compact\u003cbr\u003e• Pre-connected pads (one pair of pads for adults and chilidren)\u003cbr\u003e• Easy communication with CU-EX1 software using IrDA or SD card (multi-event recording) \u003cbr\u003e\u003cstrong\u003e\u003cem\u003eOPTIONAL\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e• Pads usage indication (Check and indicate the expiring date)\u003cbr\u003e• Adjust volume automatically depending on the circumstances.\u003cbr\u003e• Perfect for public facilities\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTO VOLUME ADJUST\u003c\/strong\u003e\u003cbr\u003ePublic places can often be noisy. Crowded stations, airports with constant announcements and streets filled with cars and people often make it difficult to hear what’s going on around you. Trying to use an AED in noisy places can be difficult if the first responder can’t clearly hear the voice prompts and instructions from the AED. The iPAD CU-SP1 listens to the ambient noise, and automatically adjusts the volume of its\u003cbr\u003eprompts to make them clear and easily heard over the background noise. When the correct volume has been reached the iPAD CU-SP1 keeps the prompts at this level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSMART PADS - SMART STORAGE!\u003c\/strong\u003e\u003cbr\u003eThe pre-connected ‘Smart’electrode pads are stored in a clear storage compartment on the underside of the unit. This ensures that the iPAD SP1 is always ready to be used in the shortest amount of time possible. The unique technology built in to the iPAD CU-SP1 and the ‘Smart’ electrode pads allows the unit to detect, when connected, if a set of pads has already been used. If they have, the user is advised of this.\u003cbr\u003eIn addition, the visual indicator on the front of the iPAD CU-SP1 indicates if the connected pads are within their life expectancy. The indicator will change when the pads have only 3 months life left before their expiry date-giving you plenty of time to arrange for replacements. The indicator will change again when the expiry date is reached. Checking the life of your pads is as quick and simple as looking at the LCD display.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCPR DETECTION \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCPR is vital to ensure that the casualty has the best chances of survival. The iPAD CU-SP1 detects if CPR is being performed when appropriate prompts and encourages the first responder. If CPR is not being performed, the iPAD CU-SP1 prompts the first responder to ‘perform CPR’. If CPR is already being performed, the iPAD CU-SP1 encourages the first responder by prompting them to ‘continue CPR’.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEASY COMMUNICATION WITH CU-EX1 SOFTWARE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGetting information from the iPAD CU-SP1 after an event is now easier than ever! Installing CU-EX1 software onto a computer allows you to see and analyse the usage history of the unit. Information such as time of ‘power on’, the casualty’s heart rhythm and shocks delivered are all presented in an easy to understand fashion. The iPAD CU-SP1 can store up to 5 events with up to 3 hours of ECG analysis on an SD memory card. The data can be transferred by either simply removing the SD card, or by using the inbuilt infra-red (IrDA) port. Having the data on an SD Memory card allows the card to be removed for analysis whilst another card is inserted, making the unit ready to use again whilst retaining the original information.\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\u003cstrong\u003e DEFIBRILLATOR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003eStandard Package\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eDefibrillator, Pads, Battery, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003eOutput Energy\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eAdult-150Joules \/\u003cbr\u003ePediatric-50Joules (Common usage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003eCharging time\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e1) Charging time : Less than 8 seconds\u003cbr\u003e2) Charging time after CPR finished : At least 8 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUSER INTERFACE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUser support\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eDetailed voice prompts and flashing\u003cbr\u003eIndicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCPR guidance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eVoice prompts for how to perform CPR for\u003cbr\u003eAdult and child patient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eControls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eOn\/Off button, I button, Shock button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIndicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\n\u003cp\u003eLCD display (Device status, Battery status, Pads status)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003ePads expiring date, Pads connection status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCPR Monitoring\u003cbr\u003eAutomatic Volume adjusting\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eENVIRONMENT\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSealing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eWaterjet proof IPX5 per IEC60529 (IP55)\u003cbr\u003eDust protected IP5X per IEC60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTemperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eOperation\/standby (0 - 40 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eVibration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eMeets MILSTD 810F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA RECORDING AND TRANSMISSION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIrDA port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eWireless transmission of event data to PC, SD Card (OPTIONAL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eInternal Memory (Nand-flash)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eECG, Event\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eStorage capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eMulti recording 5 events \/ Max 3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eData review PC Program\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eCU-EX1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePATIENT ANALYSIS SYSTEM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ePatient Analysis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eShockable Rhythms - Ventricular Fibrillation,\u003cbr\u003eVentricular Tachycardia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSensitivity\/Specificity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003eMeets AAMI DF80 Guideline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERY\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003cbr\u003e+ Type : DC 12 Volt 2.8 Ah, Lithium manganese dioxide\u003cbr\u003e+ Capacity : Minimum 100shocks (150J ) \u003cstrong\u003eHigh Capacity\u003c\/strong\u003e\u003cbr\u003e+ Type : DC 12Volt 4.2Ah, Lithium manganese dioxide\u003cbr\u003e+ Capacity : Minimum 200shocks (150J )\u003cbr\u003e\u003cstrong\u003eLifespan\u003c\/strong\u003e 5 years (High capacity battery)\u003cbr\u003e(With the condition of the temperature of operation\/\u003cbr\u003estandby, standby mode after the first initial check)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePADS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9471%;\" data-mce-style=\"width: 47.9471%;\"\u003e\n\u003cp\u003eCommon usage for\u003cstrong\u003e adult and child\u003c\/strong\u003e\u003cbr\u003eExpiring date 30 months (from the date of manufacturing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.9507%;\" data-mce-style=\"width: 48.9507%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SA Healthcare (Pty) Ltd","offers":[{"title":"Default Title","offer_id":45897993453848,"sku":"AEDSP1","price":35862.75,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1910\/0399\/files\/AEDSP1.png?v=1724328045","url":"https:\/\/shop.vertice.co.za\/products\/aed-intelligent-public-access-defibrillator","provider":"Vertice Healthcare (Pty) Ltd ","version":"1.0","type":"link"}